Electronic VFDs are speed control devices which vary the voltage and frequency to an induction motor using a technique called Pulse Width Modulation (PWM). Since they are inexpensive and reliable, VFD’s have become the preferred way to achieve variable speed operation. The following is a glossary of commonly used terms when describing or specifying Variable Frequency Drives for electric motors.

Alternating Current (AC): A periodic flow of electricity which changes direction each cycle, reaching a maximum in one direction, decreasing to null, then reversing to reach a maximum in the opposite direction.

Air Gap: The space between the rotating and stationary parts of an electric motor. Magnetic energy is transferred across this gap.

Ambient: The air surrounding a motor.

Ampere: A measure of the rate of electron flow (current). It is often abbreviated as Amp.

Breakdown Torque: The maximum torque a motor can develop at a rated voltage without stalling or experiencing an abrupt drop in speed.

Brush: The material in contact with an armature or slip ring assembly that provides the electrical connection between rotating and stationary parts of a motor.

Capacitor: A device used to store electrical charge. The unit of capacitance is the Farad.

Commutator: An assembly mounted on the shaft of a DC motor that provides the switched connections between the power supply and armature coils.

Conductor: Material which offer little opposition to the flow of electricity..

Duty Cycle: The relationship between the operating time and the idle time of an electric motor.

Eddy Current: Losses and heating in metals resulting from localized currents caused by an alternating magnetic flux.

Efficiency: The ratio of mechanical output to the electrical input power of a motor.

Electromotive Force (EMF): Induced or generated voltages in an electric circuit.

Field: The stationary part of a DC motor that provides the magnetic flux which interacts with the armature.

Flux: The magnetic field established around a current carrying conductor or a permanent magnet.

Frequency: The rate at which alternating current reverses its direction of flow expressed in cycles per second or Hertz.

Full Load Current: The current that a motor draws at rated voltage, frequency and load.

Full Load Slip: a ratio of the synchronous speed to full load speed of a motor.

Full Load Speed: The speed of the motor at rated voltage, frequency and load.

Full Load Torque: The torque that is necessary to produce rated horsepower at full load speed.

Horsepower: A measurement of power. One horsepower is equal to 746 watts.

Impedance: The vector sum of resistance and reactance used to express the total opposition a circuit offers to the flow of alternating current.

Inductance: The property of an electrical circuit which opposes a change in current due to the magnetic field induced by that current.

Inertia: The resistance of an object to a change in its state of motion. Since rotating parts do not operate at the same speed, calculating the inertia for each moving part allows them to be modeled as a single unit. It is determined by the weight of the object multiplied by the square of the radius of gyration.

Line Voltage: The mains voltage supplied to the power input terminals of an electric device.

Magnetomotive Force (MMF): The magnetic energy supplied to create a magnetic flux.

Phase: The relationship (in electrical degrees) between voltages and currents in a circuit or the spatial relationship (in angular degrees) of windings in an electric motor.

Power Factor: A measurement of the difference in phase between voltage and current in an electric circuit.

Reactance (capacitive): The property of a capacitor in a circuit which causes the voltage to lead the current.

Reactance (inductive): The property of an inductor in a circuit which causes the voltage to lag the current.

Resistance: The property of an electrical conductor which opposes the flow of electricity.

Rotor: The rotating part of an electric motor.

Service Factor: A multiplier applied to the rated horsepower of an AC motor indicating the permissible loading which may be carried under a set of specified conditions.

Slip: The ratio between the synchronous and operating speeds of an induction motor.

Stator: The stationary part of an AC motor containing the housing, steel laminations and windings.

Temperature Rise: The difference between operating and ambient temperature in a motor winding.

Torque: The turning force applied to a shaft, expressed as pound-feet (English) or Newton-meters (metric).

Voltage (Volt): The standard unit of EMF which produces a flow of current in a conductor.

Watt: A measurement of power in an electrical circuit. It is equal to one joule of energy being expended in one second.


Basic Motion Control – A Glossary of Terms Used With Variable Frequency Drives and Electric Motors Related Video:


Every member from our high efficiency sales team values customers' needs and business communication for 220v Ac Servo Drive, Panasonic Servo Drive, Hmi Control Panel, We have exported our products all over the world, especially the USA and European countries. Furthermore, all of our products are manufactured with advanced equipment and strict QC procedures to ensure high quality.If you are interested in any of our products, please don't hesitate to contact us. We will try our best to meet your needs.